Vertical Scaling MySQL
This guide will give you an overview of how KubeDB Ops Manager updates the resources(for example Memory and RAM etc.) of the MySQL database server.
Before You Begin
- You should be familiar with the following
KubeDBconcepts:
How Vertical Scaling Process Works
The following diagram shows how the KubeDB Ops Manager used to update the resources of the MySQL database server. Open the image in a new tab to see the enlarged version.

The vertical scaling process consists of the following steps:
At first, a user creates a
MySQLcr.KubeDBcommunity operator watches for theMySQLcr.When it finds one, it creates a
PetSetand related necessary stuff like secret, service, etc.Then, in order to update the resources(for example
CPU,Memoryetc.) of theMySQLdatabase the user creates aMySQLOpsRequestcr.KubeDBOps Manager watches forMySQLOpsRequest.When it finds one, it halts the
MySQLobject so that theKubeDBcommunity operator doesn’t perform any operation on theMySQLduring the scaling process.Then the
KubeDBOps Manager will update resources of the PetSet replicas to reach the desired state.After successful updating of the resources of the PetSet’s replica, the
KubeDBOps Manager updates theMySQLobject resources to reflect the updated state.After successful updating of the
MySQLresources, theKubeDBOps Manager resumes theMySQLobject so that theKubeDBcommunity operator resumes its usual operations.
Vertical Scaling Modes
KubeDB actuates vertical scaling in one of two modes, selected through the spec.verticalScaling.mode
field of the MySQLOpsRequest:
Restart(default): The operator patches thePetSetwith the new resources and restarts the Pods (one at a time, honoring the database’s failover rules) so they come back with the updated CPU and Memory. This works on every Kubernetes cluster.InPlace: The operator resizes the running containers in place using the Kubernetes in-place Pod resize (pods/resizesubresource) — no Pod restart, so scaling happens without downtime or failover. If a Node cannot accommodate the new resources (the resize is reportedInfeasible), the operator automatically falls back to theRestartbehavior for that Pod.
If spec.verticalScaling.mode is omitted, it defaults to Restart.
Note:
InPlacemode relies on the KubernetesInPlacePodVerticalScalingfeature gate, which is enabled by default from Kubernetes v1.33. On older clusters, or when the feature gate is disabled, useRestartmode.
In the next doc, we are going to show a step by step guide on updating resources of MySQL database using vertical scaling operation.